1.Use hexagon wrench to unbolt the connection of pump head and disassemble the pump head

 

2.Unscrew the diaphragm counterclockwise

 

3.If the diaphragm is damaged, replace it with a new one

 

4.Screw the normal diaphragm onto the pump body in a clockwise direction

 

5.Install the pump head back to the pump body with the outlet facing up and the inlet facing down

 

6.Screw the pump head connection bolts separately

 